loading

Turnkey Cleanroom Solutions And Hvac System Service Provider - Aircolourful

Medical door - antibacterial, moisture-proof, safe and clean 1
Medical door - antibacterial, moisture-proof, safe and clean 2
Medical door - antibacterial, moisture-proof, safe and clean 3
Medical door - antibacterial, moisture-proof, safe and clean 4
Medical door - antibacterial, moisture-proof, safe and clean 1
Medical door - antibacterial, moisture-proof, safe and clean 2
Medical door - antibacterial, moisture-proof, safe and clean 3
Medical door - antibacterial, moisture-proof, safe and clean 4

Medical door - antibacterial, moisture-proof, safe and clean

Special doors designed for medical environments have many professional advantages over ordinary doors and can meet the high standards of medical institutions for hygiene, safety and efficiency.

    oops...!

    no product data.

    Go to homepage

    Hygiene and infection control advantages

     Antibacterial surface treatment

    Antibacterial coating or overall stainless steel material effectively inhibits bacterial growth

    Smooth surface without pores to avoid pathogens hiding

    Easy to clean and disinfect design

    No threshold, no dead corner structure, easy to clean thoroughly

    Corrosion-resistant material can withstand repeated wiping with high-strength disinfectants

    Excellent airtight performance

    Special sealing structure prevents cross-contamination of air

    undefined
    详情图2 (4)

    Intelligent management advantages

     Non-contact opening

    Optional foot sensor, hand sensor or automatic door design to reduce the risk of contact transmission

    Optional access control to achieve permission management

    Advantages of professional customization

     Flexible size, can be customized to large size to meet the special needs of operating room and imaging department

    The thickness of the door can be adjusted according to the sound insulation requirements

    Observation window design

    Standard or optional double-layer tempered glass observation window

    Color identification system

    A variety of colors are available, in line with the hospital department identification specifications

    详情图3 (4)
    详情图4 拷贝 (7)

    Intelligent control

     Equipped with variable air volume fan unit PLC control system and sensor system, etc. The control panel is located on the front of the working area inside the equipment. The control panel adopts a touch screen control panel, which can control the start and stop of the fan, adjust the fan working conditions, and adjust the wind speed required in the working area. There is a differential pressure gauge next to it to test the resistance of the filter. There is also an exhaust adjustment plate inside the air supply box to adjust the exhaust volume of the equipment within a reasonable range.


    Real-time monitoring of pressure difference: digital display monitors wind speed and pressure difference, and alarms for over-limit.

    illustrate

    1 (6)
    1. Buzzer
    2 (9)
    2. Wind speed sensor
    3 (8)
    3. PAO injection port
    4 (6)
    5. Medium efficiency differential pressure gauge
    5 (4)
    6. Primary efficiency differential pressure gauge
    6 (3)
    7. High efficiency differential pressure gauge
    7
    8. Centralized control panel
    8
    9. Dustproof socket
    详情图4 拷贝 (7)
    11. Exhaust mesh
    详情图3 拷贝 (10)
    12. Start button
    详情图2 拷贝 (9)
    13. Emergency stop
    详情图1 拷贝 (10)
    14. Negative pressure area
    主图4 拷贝 (8)
    15. Air duct
    主图3 拷贝 (8)
    17. Fan
    主图2 拷贝 (11)
    24. Liquid tank high efficiency
    主图1 拷贝 (11)
    19. Primary efficiency filter
    详情图1 拷贝2
    20. Liquid tank high efficiency 1
    详情图1 拷贝 (9)
    21. Positive pressure area
    主图2 拷贝 (10)
    23. Flow equalization membrane
    产品规格图

    Product advantages

     The fan has long life, low noise, maintenance-free, and low vibration;

    The wind speed is automatically constant or adjusted in steps;

    Double-layer negative pressure structure, no risk of leakage;

    The liquid tank design ensures perfect sealing;

    Excellent air uniform distribution performance;

    Consistent inside and outside, clean and without dead corners.

    undefined

    Product Specification

    Dimensions (mm)

    Working area size (mm)

    Rated air volume (m'/h)

    Wind speed (m/s)

    Cleanliness level

    Noise(dB)|

    Illuminance(Lux)

    Control method

    Power(KW)

    1200X1200X2500

    1100X700X2000

    1300-1500

    0.45+20%

    Class A

    72

    ≥300

    Inverter control LCD control

    0.75

    1300X1300X2500

    1200X800X2000

    1600-1800

    0.75

    1500X1300X2500

    1400X700X2000

    2000-2200

    1.5

    2000X1300X2500

    1900X800X2000

    2500-2700

    1.5

    2000X1500X2500

    1900X1000X2000

    3400-3600

    2.2

    2000x1800X2500

    1900X1300X2000

    4500-4900

    2.2

    Get A Free Quote
    If you have any questions about our products or services, feel free to reach out to customer service team.
    Related Products
    no data
    Ready to work with us ?
    Contact Us
    Copyright © 2025 Shenzhen Aircolourful Environment Technology Co., Ltd  | Sitemap  | Privacy Policy
    Customer service
    detect